로그인 회원가입
icon_bulk_order대량 주문 Acrobiosystems for English
0
장바구니가 비어 있습니다
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0-9
Your Position: > Kits > BSA > RES-A001

resDetect™ BSA ELISA Kit

For research use only.
    Product Details
    Assay TypeSandwich-ELISA
    AnalyteBSA (Bovine serum albumin)
    Format96T
    Regulatory StatusRUO
    Sensitivity<0.5ng/mL
    Standard Curve Range0.5ng/mL-40.5ng/mL
    Assay Time1.5 hr
    Suitable Sample TypeFor the quantitative determination of BSA (Bovine serum albumin)
    Sample volume50μL
  • Background
    Most commercial formulations of serum free media contain significant amounts of albumin and transferrin either of bovine or human origin, and insulin from various species. When the intended product may be used as a therapeutic agent in humans or animals the product should be highly purified.Efforts to reduce trace media impurities to the lowest levels practical through optimal process design, qualification, and final

    product testing require a highly sensitive and reliable analytical method.

  • Application

    The kit is developed for the detection and quantitative determination of BSA. It is used as a tool to aid in optimal purification process development and in routine quality control of in-process streams as well as final product by various biotechnological processes such as cell or tissue culture .

    It is for research use only.

  • Storage
    1. Unopened kit should be stored at 2℃-8℃ upon receiving.

    2. Find the expiration date on the outside packaging and do not use reagents past their expiration date.

    3. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

    Materials Provided
    IDComponentsSize
    RES01-C01Pre-Coated Anti-BSA Antibody Microplate1 plate
    RES01-C02ABSA (Bovine serum albumin) Standard (200ng/mL)500 μL
    RES01-C02BBSA (Bovine serum albumin) Standard 5 (40.5ng/mL)500 μL
    RES01-C02CBSA (Bovine serum albumin) Standard 4 (13.5ng/mL)500 μL
    RES01-C02DBSA (Bovine serum albumin) Standard 3 (4.5ng/mL)500 μL
    RES01-C02EBSA (Bovine serum albumin) Standard 2 (1.5ng/mL)500 μL
    RES01-C02FBSA (Bovine serum albumin) Standard 1 (0.5ng/mL)500 μL
    RES01-C02GBSA (Bovine serum albumin) Standard 0 (0ng/mL)500 μL
    RES01-C03HRP-Anti-BSA Antibody100 μL
    RES01-C041×Sample Dilution Buffer50 mLX2
    RES01-C0520×Washing Buffer25 mL
    RES01-C06Substrate Solution12 mL
    RES01-C07Stop Solution8 mL
  • Assay Principles
    The resDetect™ BSA ELISA Kit is used to measure the levels of BSA (Bovine serum albumin) by employing a standard sandwich-ELISA format. The micro-plate in the kit has been pre-coated with anti-BSA antibody. Firstly adding standards and samples, next add the HRP-Anti-BSA Antibody to the plate . At last, load the tetramethylbenzidine (TMB) substrate into the wells and monitor a blue color. The reaction is stopped by the addition of a stop solution and the color turns yellow. The intensity of the absorbance can be measured at 450nm and 630nm on a microtiter plate reader. The OD Value reflects the amount of BSA (Bovine serum albumin).
Typical Data Please refer to DS document for the assay protocol.
 BSA TYPICAL DATA

Detection of BSA ( Bovine serum albumin) by ELISA Assay.
Immobilized Anti-BSA Antibody can bind BSA (Bovine serum albumin) Detection was performed using HRP-Anti- BSA Antibody with sensitivity of 0.5 ng/mL (QC tested). For each experiment, a standard curve needs to be set for each micro-plate, and the specific OD value may vary depending on different laboratories, testers, or equipments. The following example data is for reference only.

Validation
Intra-Assay Statistics

Three samples of known concentration were tested ten times on one plate to assess intra-assay precision , Intra-Assay Precision CV≤15%.

 BSA INTRA-ASSAY STATISTICS
Inter-Assay Statistics

Three samples of known concentration were tested in ten separate assays to assess inter-assay precision, Inter-Assay Precision CV≤15%.

 BSA INTER-ASSAY STATISTICS
Accuracy

Five samples of known concentration were tested ten times to assess Accuracy , Accuracy recovery rate 80-120%.

 BSA ACCURACY
Interference effect

We have conducted interference effect test about frequently-used buffers, they have excellent buffer compatibility. For specific buffers, it is recommended that you verify recovery to determine the minimum dilution ratio.

 BSA INTERFERENCE EFFECT
Specificity

High, medium and low concentrations of BSA were added to Human serum (v/v 1%), Horse serum (v/v 10%) , Human Serum Albumin (1.25 mg/mL) and Rabbit serum (v/v 10%), the recovery rate of BSA was used as the specific validation index.

 BSA SPECIFICITY

High, medium and low concentrations of BSA were added to MDCK( 2×106 cells/mL), HEK293( 3.5×106 cells/mL) , CHO( 2×106 cells/mL) and T-lymphocyte( 2.15×106 cells/mL) the recovery rate of BSA was used as the specific validation index.

 BSA SPECIFICITY
  • Clinical and Translational Updates

코멘트 (0)


재고상품 출발날짜: 영업일 기준 4일

가격(KRW) : 420,000

보급 및 전시



Datasheet & Documentation

DMF 신청
DMF (Drug Master File)

관련 제품

신제품

문의와 컨텐츠

This web search service is supported by Google Inc.

totop